Standard for the Installation of Stationary Pumps for Fire by Gayle Pennel

By Gayle Pennel

Show description

Read Online or Download Standard for the Installation of Stationary Pumps for Fire Protection PDF

Similar technique books

Recent developments of electrical drives: best papers from the International Conference on Electrical Machines, ICEM'04

Fresh advancements of electric units  is composed of the papers that have been offered on the XVI foreign convention on electric Machines - ICEM2004, which was once held in Cracow, Poland on September 5-8, 2004. The contributions chosen for the ebook conceal a large spectrum of concept and perform, therefore they're deeply rooted in engineering difficulties, being concurrently of excessive theoretical point.

Engineering of Functional Skeletal Tissues (Topics in Bone Biology, 3)

This can be the third quantity in a chain of studies established at the unmarried significant subject of bone substitute, discussing the biology of stem cells and phone signs, the data had to make stem cell-engineered bone tissue a fact, and the way to avoid bone allograft an infection. worthwhile as a followup to its predecessors, and as a stand-alone reference, it is going to curiosity a vast viewers from orthopedists and bioengineers to dentists.

Extra info for Standard for the Installation of Stationary Pumps for Fire Protection

Sample text

2 and shall be permitted to be installed in accordance with NFPA 70. 3 are met, the voltage at the controller line terminals shall not drop more than 15 percent below normal (controller-rated voltage) under motor-starting conditions. 1 shall not apply to emergencyrun mechanical starting. 3), provided a successful start can be demonstrated on the standby gen-set. 4 The voltage at the contactor(s) load terminals to which the motor is connected shall not drop more than 5 percent below the voltage rating of the motor when the motor is operating at 115 percent of the full-load current rating of the motor.

3 For installations in a wet pit, this suction strainer shall be required in addition to the intake screen. (See Figure A. 5 Fittings. 2 Automatic Air Release. 5 in. (38 mm) pipe size or larger automatic air release valve shall be provided to vent air from the column and the discharge head upon the starting of the pump. 2 This valve shall also admit air to the column to dissipate the vacuum upon stopping of the pump. 3 This valve shall be located at the highest point in the discharge line between the fire pump and the discharge check valve.

2(5) for the normal source of power, no more than one disconnecting means and associated overcurrent protection device shall be installed in the power supply to the fire pump controller. 3 is installed, the disconnecting means shall meet all of the following requirements: It shall be identified as being suitable for use as service equipment. (2) It shall be lockable in both the closed position and the open position. (3)* It shall be located remote from other building disconnecting means. (4) * It shall be located remote from other fire pump source disconnecting means.