BPVC-I - 2007 BPVC Section I : Power Boilers by ASME

By ASME

This part presents specifications for all equipment of building of strength, electrical, and miniature boilers; hot temperature water boilers utilized in desk bound carrier; and tool boilers utilized in locomotive, moveable, and traction carrier. ideas relating use of the V, A, M, PP, S and E Code image stamps also are incorporated. the foundations are acceptable to boilers during which steam or different vapor is generated at a pressures exceeding 15 psig, and hot temperature water boilers meant for operation at pressures exceeding a hundred and sixty psig and/or temperatures exceeding 250 measure F. Superheaters, economizers, and different strain components attached on to the boiler with out intervening valves are regarded as a part of the scope of part 1.

Show description

Read Online or Download BPVC-I - 2007 BPVC Section I : Power Boilers PDF

Similar technique books

Recent developments of electrical drives: best papers from the International Conference on Electrical Machines, ICEM'04

Fresh advancements of electric units  is composed of the papers that have been offered on the XVI foreign convention on electric Machines - ICEM2004, which used to be held in Cracow, Poland on September 5-8, 2004. The contributions chosen for the ebook conceal a large spectrum of concept and perform, hence they're deeply rooted in engineering difficulties, being concurrently of excessive theoretical point.

Engineering of Functional Skeletal Tissues (Topics in Bone Biology, 3)

This can be the third quantity in a chain of experiences headquartered at the unmarried significant subject of bone alternative, discussing the biology of stem cells and cellphone indications, the information had to make stem cell-engineered bone tissue a fact, and the way to avoid bone allograft an infection. precious as a followup to its predecessors, and as a stand-alone reference, it's going to curiosity a extensive viewers from orthopedists and bioengineers to dentists.

Extra info for BPVC-I - 2007 BPVC Section I : Power Boilers

Sample text

12 A VIE installation comprises: a. a vacuum insulated tank to store the bulk liquid at the appropriate operating pressure; b. a pressure raising system to maintain the VIE operating pressure; c. a vaporiser system to convert the liquid into gaseous product at ambient temperature. 13 The control panel and instrumentation for the VIE are normally mounted centrally at the front of the vessel. Pressure vessel details are given on a plate mounted on the outer vessel. The vessel must be clearly labelled with the product name.

In the event of such a cable fault, a red “system fault” lamp should be illuminated on the alarm signal status unit, together with the appropriate alarm condition. 23 A permanently connected reserve supply system must be provided for all MGPS including nitric oxide systems (excluding 700 kPa surgical air systems), for emergency use or to permit servicing or repair. 24 The reserve supply should be designed, when practicable, to provide the same flow rate as the primary system and have sufficient connected capacity to supply the pipeline for at least 4 hours.

3 The nominal and usable capacity of the cylinders commonly used on manifolds are given in Table 14 (the figures are the equivalents at standard temperature and pressure). Table 14 Capacities of medical gas cylinders used on manifolds Gas Nominal capacity (litres) at 137 bar g Oxygen J size Nitrous oxide J size G size Nitrous oxide/oxygen mixtures G size Medical air J size Oxygen/carbon dioxide mixture (5% CO2) J size Nitric oxide AU size Nitric oxide AK size * ** **Usable capacity (litres) 6,800 18,000 9,000 5,000 6,540 6,400 6,220 5,550 6,800 6,540 1,500* 4,000* – – 8,900 4,740 This may be subject to change.

Download PDF sample

Rated 4.17 of 5 – based on 39 votes